[Feb-2022] 500-920 Pre-Exam Practice Tests Exam Questions and Answers for Cisco Channel Partner Data Center Study Guide [Q23-Q42]

Share

[Feb-2022] 500-920 Pre-Exam Practice Tests | Exam Questions and Answers for Cisco Channel Partner Data Center Study Guide

Cisco Data Center Unified Computing Infrastructure Troubleshooting Certification Sample Questions

NEW QUESTION 23
Which statement is true regarding the UCS Manager GUI is showing "Overall Status Unassociated" in the General tab for a C-series server?

  • A. The server is not properly connected
  • B. The server has a service profile assigned, but has connectivity issues with UCS Manager
  • C. The server has been properly connected, but has not been discovered by UCS Manager
  • D. The server does not have a service profile assigned, but has been discovered by UCS Manager

Answer: A

 

NEW QUESTION 24
In a Cisco UCS Manager, if all KVM sessions to each server fail to start, what is likely causing the problem?

  • A. The workstation you are using to connect to the KVM session is the problem
  • B. The Fabric Interconnect to which you are connected has a problem
  • C. The I/O Modules in the chassis are the problem
  • D. Cisco UCS Manager has a problem

Answer: A

 

NEW QUESTION 25
An overvoltage condition has occurred on a UCS server However the Cisco IMC System Event Log (SEL) file is full What is the resulting fault logging action?

  • A. The overvoltage condition event will not be recorded in the SEL.
  • B. The newest entry in the SEL will be overwritten by the overvoltage condition event.
  • C. The SEL is not used to record server related events, such as overvoltage conditions.
  • D. The oldest entry in the SEL will be overwritten by the overvoltage condition event

Answer: A

 

NEW QUESTION 26
After performing a UCS firmware upgrade, which two UCS components will require updated drivers? (Choose two )

  • A. Cisco UCS Manager
  • B. Cisco Fabric Interconnects
  • C. VIC Cards and Fiber Channel HBAs
  • D. RAID Controllers

Answer: B,C

 

NEW QUESTION 27
Which statement regarding the UCS C-senes connectivity modes best describes connectivity options in a UCS Manager integrated environment?

  • A. UCS C-series servers may be connected with or without the use of Fabric Extenders (FEX) in environments running UCS Manager Software Release 2 2 or later
  • B. All UCS C-series servers in a single UCS Manager domain must share the same connectivity model
  • C. UCS C-series servers may be connected to multiple UCS Manager domains at the same time
  • D. UCS C-series servers must be connected to Fabric Interconnects using Fabric Extenders (FEX)

Answer: A

 

NEW QUESTION 28
The command show interface veth 705 is telling you that the bound interface is Ethernet 3/1/2 What is the location of the blade that has veth 705 associated to it?

  • A. Chassis 3. Slot 2
  • B. Chassis 3, Slot 1
  • C. There is not enough information
  • D. Chassis 1. Slot 2

Answer: B

 

NEW QUESTION 29
What is the result of enabling the Core File Exporter in UCS Manager?

  • A. If a subsequent triggering event occurs, a core dump will be generated and sent by TFTP
  • B. A core dump must be remotely activated by Cisco TAC.
  • C. A core dump file will be immediately created and transmitted using HTTP protocol
  • D. A core dump will immediately be generated and will be exported

Answer: D

 

NEW QUESTION 30
Which two statements describes connecting the IO Modules in the UCS chassis to the Fabric interconnects? (Choose two )

  • A. Connect Fl-B to the IOM B of each chassis
  • B. Connect Fl-A to IOM A and IOM B in each chassis
  • C. Connect Fl-B to the IOM A of each chassis
  • D. Connect Fl-A to the IOM A of each chassis
  • E. Connect Fl-B to IOM A and IOM B in each chassis
  • F. Connect Fl-A to the IOM B of each chassis

Answer: A,D,F

 

NEW QUESTION 31
Which two interfaces allow access to Cisco UCS Manager? (Choose two )

  • A. Cisco UCS Manager XML API
  • B. Cisco UCS Manager GUI
  • C. Cisco KVM
  • D. Cisco IMC

Answer: A,B

 

NEW QUESTION 32
Which statement best describes managing Cisco UCS servers using NX-OS CLI on the Fabric Interconnects?

  • A. The NX-OS CLI on the Fabric Interconnects allows you to manage QoS parameters on the Fabric Interconnects and an upstream LAN switch
  • B. The NX-OS CLI on the Fabric Interconnects allows you to change the connectivity configuration between the servers and Fabric Interconnects
  • C. The NX-OS CLI on the Fabric Interconnects allows you to change the connectivity configuration between the Fabric Interconnects and an upstream LAN switch.
  • D. The NX-OS CLI on the Fabric Interconnects allows you to view, but not change the connectivity configuration between the Fabric Interconnects and an upstream LAN switch.

Answer: C

 

NEW QUESTION 33
When server is booting from SAN, which command verifies the PLOGI sessions with the target?

  • A. FCIist
  • B. Lunlist
  • C. FCMap
  • D. Lunmap

Answer: B

 

NEW QUESTION 34
Which statement is true when using SPAN for Fibre Channel (FC) Traffic?

  • A. FC port on Cisco UCS 6238UP can be used as a SPAN source
  • B. When defining FC uplink port as the SPAN destination, system will automatically stop using that port as an uplink port
  • C. Any port can be used as a SPAN destination port Even if it is defined as Eth uplink port it will be automatically converted to FC uplink port
  • D. For FC SPAN sessions we do not have to specifically enable the monitoring session

Answer: A

 

NEW QUESTION 35
Which ethernet port type is used when configuring UCS Fabric Interconnect connections to Cisco UCS C-series servers?

  • A. Server Port
  • B. Uplink Port
  • C. Direct Connect Port
  • D. Service Profile Port

Answer: B

 

NEW QUESTION 36
If a Cisco UCS B-Series server fails to initialize, which method of access is required to troubleshoot?

  • A. Use Cisco UCS Manager GUI to troubleshoot initialization
  • B. Use KVM console to troubleshoot initialization
  • C. Use direct console access to troubleshoot initialization
  • D. Use Cisco UCS Manager API to troubleshoot initialization

Answer: B

 

NEW QUESTION 37
Which two formats can be configured for Cisco's Call Home email message? (Choose two )

  • A. JSON
  • B. CSV
  • C. XML
  • D. Full text

Answer: C,D

Explanation:
Call Home Message Formats The Call Home feature offers the following message formats: * Short Text - Suitable for pagers or printed reports. * Plain Text - Full formatted message information suitable for human reading. * XML - Matching readable format using Extensible Markup Language (XML) and Adaptive Markup Language (AML) document type definitions (DTDs). The XML format enables communication with the Cisco TAC. For user-defined destination profiles, the format options are long-text, short-text, or XML. The default is XML. For the predefined Cisco TAC profile, only XML is allowed.
Reference:
http://www.audentia-gestion.fr/cisco/smart-call-home-feature-guide-1611.pdf

 

NEW QUESTION 38
After installing a new UCS M4 server, which two Cisco Integrated Management Controller connectivity options do you have? (Choose two )

  • A. In-band Access
  • B. Web Access
  • C. Out-of-Band Access
  • D. XML API Access
  • E. SNMP

Answer: A,D

 

NEW QUESTION 39
......


Cisco 500-920 Exam Syllabus Topics:

TopicDetails
Topic 1
  • Troubleshoot storage area networks, including Fibre Channel, FCoE, zoning, NPV, and NPIV
Topic 2
  • Troubleshoot data center unified computing
Topic 3
  • Troubleshoot FEX
Topic 4
  • Troubleshoot virtualization solutions

 

Cisco Exam Practice Test To Gain Brilliante Result: https://examsboost.actualpdf.com/500-920-real-questions.html